The HI 9126 is the next generation in professional, accurate, easy-to-use pH meters. These meters are designed to provide laboratory results in a sleek, simple and portable design.
An extended dual-level LCD displays pH and temperature readings simultaneously while also displaying the electrode status. The HI 9126 also guides the user through the calibration process with clear on-screen guides. The meter is provided with a series of diagnostic features to improve measurement consistency and reliability.
The HI 9126 can also measure ORP using optional probes.
The meter is provided with the BEPS (Battery Error Prevention System) feature, which automatically turns the instrument off when the battery level is too low to ensure reliable readings.
- Range: pH: -2.00 to 16.00 pH
- Range: mV: ±699.9 mV; ±1999 mV
- Range: Temperature: -20.0 to 120.0 °C (-4.0 to 248.0 °F)
- Resolution: pH: 0.01 pH
- Resolution: mV: 0.1 mV; 1 mV
- Resolution: Temperature: 0.1 °C; 0.1 °F;
- Accuracy: pH: ±0.01 pH
- Accuracy: mV: ±0.2 mV; ±1 mV
- Accuracy: Temperature: ±0.4 °C; ±0.8 °F
- Calibration Check: checks the electrode status during calibration
- pH Calibration: automatic 1 or 2 point with 5 memorized buffer values (4.01, 6.86, 7.01, 9.18, 10.01)
- Offset Calibration: ±1 pH
- Slope Calibration: From 80 to 108%
- Temperature Compensation: automatic or manual, -20 to 120°C (-4 to 248°F)
- pH Electrode: HI 1230B, double junction, gel filled, BNC connector and 1 m (3.3’) cable (included)
- Temperature Probe: HI 7662 with 1 m (3.3’) cable (included)
- Input Impedance: 1012 Ohm
- Battery Type / Life: (4) 1.2V AAA rechargeable / approx 200 hours of continuous use (with backlight off); auto-off after 20 minutes of non-use (can be disabled)
- Environment: 0 to 50°C (32 to 122°F); RH max 100%
- Dimensions: 192 x 71.6 x 36 mm (7.5 x 2.8 x 1.4’’)
- Weight: 525 g (18.5 oz.)
HI 9126 features up to 200 hour extended battery life to guarantee long operation in the field. When the batteries are low, you don't have to worry about carrying a spare set with you - the batteries can be recharged with Hanna's inductive recharger. Simply leave the meter on the recharger for a few hours and you're ready to go. The recharger can either be plugged into a standard 115V or 230V socket using the appropriate adapter.
- Exclusive Calibration Check
- Backlit, extended display
- Extended pH and temperature ranges
- Users are guided through operations on LCD
- Electrode condition monitoring
- 7 standard buffers for calibration and 2 custom buffers
- Display hold and memory storage
- User-selectable calibration timeout reminder
- Measures in °C or °F
- Waterproof
- Powered by rechargeable batteries
- Inductive battery recharger docking station included
- BEPS (Battery Error Prevention System)
- pH electrode, temperature probe and hard carrying case included
HI 9126 is supplied with HI 1230B pH electrode, HI 7662 temperature probe, pH 4 and pH 7 buffer sachets, 100 mL plastic beaker, (4) rechargeable batteries, inductive charger, rugged carrying case and instructions.
|